225 kva three phase step up transformer
Your Trusted Partner for Transformers & Reactors Manufacturing

225 kva three phase step up transformer

No one wants to swap out their whole system just to match voltage. That’s why so many of our customers rely on a 225 kVA step-up transformer to bridge 208V or 240V up to 480V—clean, stable, and code-compliant.

We’ve built these units for hospitals upgrading HVAC loads, OEMs shipping control panels across borders, and BESS integrators tying into high-voltage gear. Dry-type, air-cooled, and fully pre-wired to spec—no guesswork onsite.

Test reports, tap settings, labeled terminals—it’s all standard. We don’t overcomplicate a job that just needs solid voltage conversion.

Photovoltaic (Solar)

In a residential solar project in Arizona, USA, the 225 kVA step-up transformer plays a critical role in lifting inverter output from 240V to the local grid’s 480V standard. The EPC contractor chose dry-type units for rooftop safety compliance, and the compact footprint fit tight utility closets without ventilation upgrades.

Energy Storage

A battery integrator in the Netherlands used our 225 kVA step-up transformers to connect low-voltage inverters (208V) to 400V commercial building mains. Since this BESS was deployed indoors, air-cooled dry-type units with Class H insulation were essential for both thermal management and fire safety.

Data Centers

In an Irish edge data center expansion, 225 kVA transformers were deployed to step up 240V distribution voltage to 415V to support upgraded PDUs and cooling systems. The engineering team highlighted the need for a UL-labeled dry-type transformer that could be installed close to load racks with minimal noise.

Wind + Hydrogen

At a hybrid wind-to-hydrogen site in coastal Spain, each electrolyzer module required 480V input while the turbine-fed grid operated at 240V. A series of 225 kVA step-up units solved this mismatch, enabling modular deployment without redesigning site-wide infrastructure. Dry-type format kept the system maintenance-friendly in remote terrain.

Medical

In a hospital lab retrofit in Munich, Germany, a 225 kVA step-up transformer was used to boost 230V to 400V for the integration of a new sterilization suite and MRI power backup. The facility team required a certified, low-noise, dry-type unit to comply with indoor medical installation standards.

CertificationUL
PhaseThree Phase
Rated capacityUP TO 3000KVA Customized
Frequency50/60Hz
Work EfficiencyUP TO 99.05%
Protection ClassIP00/IP20/IP23/IP40/IP44/IP54
Winding MaterialCopper or Aluminum
Insulation levelClass F (155°C) Class H (180°C) Class N (200°C) Class R (220°C)
Designed lifetime≥30 years
Cooling MethodAir Cooling
Wiring ConfigurationΔ-Y (Delta-Star)/Y-Y (Star-Star)/Δ-Δ (Delta-Delta)/Y-Δ (Star-Delta) /Δ-Z (Delta-Zigzag)/ Y-Z (Star-Zigzag)
Noise≤35 dB (1 meter)
Three Phase Transformer Catalog
500 kva 3 phase to single phase transformer225 kva single phase step up transformer
500 kva single phase to 3 phase transformer200kva transformer single phase to 3 phase
500 kva single phase to three phase transformer1000 kva 3 phase buck boost transformer
1000 kva 1 phase to 3 phase transformer1000 kva three phase to single phase transformer
750 kva transformer 3 phase boost transformer200kva 3 phase 208 to 480 transformer
200kva 1 phase buck boost step up transformer167 kva 3 phase step up transformer 240 to 480
150 kva 480 3 phase to 120 single phase transformer100 kva 480v to 220v 3 phase transformer
100 kva step up transformer 220 to 440 3 phase167 kva 3 phase step down transformer 240 to 208
167 kva 3 phase step up transformer 208 to 480150 kva 3 phase transformers for sale
100 kva step up transformer 220 to 440 3 phase100 kva step down transformer 480 to 240 3 phase

Releted Products

⚡ Clean Power, Elevated — Three Phase Step-Up Transformers, Built for Your System

Most commercial buildings, panels, and control systems don’t come pre-matched to your load. That’s where a three phase step up transformer comes in—raising 208V or 240V to 400V or 480V without overhauling your infrastructure.

At Shinenergy, we build step-up transformers tailored to the job—whether it’s single phase to three phase step up, generator balancing, or voltage correction for export systems. Copper or aluminum windings, delta or wye connections—we’ll match your grid and your gear.

Every transformer ships with tested taps, wiring diagrams, and certification on request. You worry about the install. We’ll make sure the voltage is right the first time.

Are all step up transformers three phase?

Not always. Step-up transformers can be single-phase or three-phase depending on your system. But for commercial and industrial applications, three phase step up transformers are by far the most common.

How does a step up transformer work on three phase power?

A three phase step up transformer increases voltage across all three phases simultaneously—usually from 208V or 240V up to 400V or 480V—using either delta or wye connections. It’s built for balanced loads and continuous operation.

How to wire a three phase step up transformer safely?

We always provide terminal labels and a full wiring guide. Whether you’re using a step up three phase transformer in delta-wye or wye-wye configuration, we’ll help confirm your source/load compatibility before shipping.

Can you build a single phase to three phase step up transformer?

Sort of. While true phase conversion requires more than a transformer, we often combine a single phase to three phase step up transformer with a rotary phase converter or solid-state controller to create a full solution.

What’s a typical step up/step down transformer configuration for three phase?

The most common setup is a three phase step up transformer with delta input and wye output, or vice versa. Some panels use dual-voltage windings or center taps, depending on the voltage range needed.

I saw a 20kVA 208V to 480V step up transformer online. Do you offer that size?

Yes, we build custom sizes—from small units like 20kVA 208V to 480V step up transformers to large dry-type builds for entire buildings. You send the voltage and load—we’ll size it right.

Send Your Inquiry
Quick Quote
Scroll to Top