Three Phase step down transformer 240v to 100v
Your Transformer & Inductor Manufacture

Three Phase step down transformer 240v to 100v

Custom Transformer Specifications

  • UL Certification standards
  • 10KVA-3000KVA Rated power
  • 50Hz/60 Hz Frequency
  • 80°C -150°C Temperature Rise
  • Class F/H/N/R Insulation Class
  • Copper/Aluminum winding materials
  • Δ-Y/Y-Y /Δ-Δ /Y-Δ/Δ-Z/Y-Z/ Wiring Configurations
  • IP00/IP20/IP23/IP40/IP44/IP54
  • Vacuum Pressure Impregnated Windings
  • Energy Efficient

Maximizing Solar Power Efficiency | Shinenergy Three Phase Step Down Transformer 240V to 100V

Shinenergy’s Three Phase Step Down Transformer 240V to 100V is engineered to meet the unique demands of photovoltaic (PV) systems, delivering efficient and stable voltage conversion for optimized solar energy performance. By stepping down 240V to 100V, our transformers enhance energy conversion efficiency, helping customers maximize returns on their solar investments. With an in-depth understanding of the renewable energy landscape and tailored solutions, Shinenergy supports businesses in optimizing system performance, ensuring both operational efficiency and a competitive edge. Choosing Shinenergy means boosting your solar project’s energy output and financial returns, driving long-term sustainability and profitability.

Elevating Energy Storage System Performance | Shinenergy Three Phase Step Down Transformer 240V to 100V

Shinenergy’s Three Phase Step Down Transformer 240V to 100V is a key component in advancing the performance of energy storage systems. With precise voltage conversion, this transformer steps down 240V to 100V, optimizing power management and ensuring system stability. Specifically designed for the energy storage industry, our solutions guarantee long-term operational reliability, helping clients navigate power management challenges and reduce costs. Partnering with Shinenergy enables businesses to fully harness their energy storage solutions, meeting evolving energy demands while driving profitability in a highly competitive market.

Ensuring Data Center Power Efficiency | Shinenergy Three Phase Step Down Transformer 240V to 100V

Power efficiency and reliability are critical in data centers, and Shinenergy’s Three Phase Step Down Transformer 240V to 100V delivers consistent and accurate voltage conversion for seamless data center operations. By stepping down voltage from 240V to 100V, our transformers protect IT infrastructure, minimize the risk of downtime, and optimize overall power management, helping reduce energy costs. By choosing Shinenergy, you’ll strengthen your data center’s operational efficiency and ensure long-term stability, providing uninterrupted service and gaining a significant competitive advantage in the market.

Powering Wind and Hydrogen Energy Projects | Shinenergy Three Phase Step Down Transformer 240V to 100V

Shinenergy’s Three Phase Step Down Transformer 240V to 100V are designed to meet the rigorous demands of renewable energy projects, including wind and hydrogen. Even in extreme environments, our transformers deliver reliable and efficient voltage conversion, ensuring peak operational performance. With Shinenergy’s advanced power management technology, businesses can optimize their renewable energy operations while reducing costs. Partnering with Shinenergy ensures not only long-term commercial success but also supports the global transition to sustainable and cleaner energy solutions.

Ensuring Medical Power Stability | Shinenergy Three Phase Step Down Transformer 240V to 100V

In the medical industry, where stable power is crucial for life-saving equipment, Shinenergy’s Three Phase Step Down Transformer 240V to 100V ensures accurate and reliable voltage conversion. Our transformers are designed to safeguard critical medical devices, adhering to strict industry standards for safety and reliability. By improving hospital power management and reducing equipment downtime, Shinenergy’s solutions help healthcare facilities maintain continuity of care. By partnering with Shinenergy, you’ll ensure a stable power supply, allowing medical professionals to focus on patient care, while we support your facility’s operational efficiency and improve patient outcomes.

Certification UL
Phase Three Phase
Rated capacity UP TO 3000KVA Customized
Frequency 50/60Hz
Work Efficiency UP TO 99.05%
Protection Class IP00/IP20/IP23/IP40/IP44/IP54
Winding Material Copper or Aluminum
Insulation level Class F (155°C) Class H (180°C) Class N (200°C) Class R (220°C)
Designed lifetime ≥30 years
Cooling Method Air Cooling
Wiring Configuration Δ-Y (Delta-Star)/Y-Y (Star-Star)/Δ-Δ (Delta-Delta)/Y-Δ (Star-Delta) /Δ-Z (Delta-Zigzag)/ Y-Z (Star-Zigzag)
Noise ≤35 dB (1 meter)
Step Down Three Phase Transformer catalog
Step Down Three Phase 480 to 240 transformer Step Down Three Phase 480 208 transformer Step Down Three Phase 480/220 transformer Step Down Three Phase 480 to 230 transformer Step Down Three Phase 480 to 400 volt transformer 480v to 230v 3 phase transformer
Step Down Three Phase 240v to 110v transformer Three Phase 240v to 120v step down transformer Three Phase 240 to 208 step down transformer Three Phase 120v to 100v step down transformer Three Phase 600v to 220v step down transformer Step Down Three Phase 208v to 120v transformer
Three Phase step down transformer 220v to 110v Three Phase 440 to 220 step down transformer Three Phase 460 to 230 step down transformer 3 phase Three Phase step down transformer 240v to 100v Three Phase 240v to 220v step down transformer Three Phase step down transformer 480 to 120
Three Phase 480 to 220 step down transformer Three Phase 480 to 230 step down transformer Three Phase 600v to 110v step down transformer Three Phase 600v to 120v step down transformer Three Phase 240v to 100v step down transformer Three Phase step down transformer 277 to 120
Rated capacity
1kva step down transformer 2kva step down transformer 5kva step down transformer 5 kva step down transformer 10 kva step up transformer 10kva step down transformer 15 kva step down transformer 20 kva step down transformer
25 kva step down transformer 30kva step down transformer 30 kva step down transformer 45 kva step down transformer 50 kva step down transformer 75 kva step down transformer 150 kva step down transformer 500 kva step down transformer
500 watt transformer 1000 watt transformer 1000w step down transformer 1500w step down transformer 1500 watt transformer 2000w step down transformer 2000 watt step down transformer 3000w step down transformer

Releted Products

Enhance Operational Efficiency with Shinenergy’s Three Phase 240V to 100V Step Down Transformer

Shinenergy’s Three Phase 240V to 100V Step Down Transformer is expertly engineered to meet the demanding requirements of industrial and commercial applications. By effectively stepping down 240V to 100V, our transformers deliver stable, reliable power, significantly reducing energy consumption while minimizing equipment failure risks. Whether your business operates in manufacturing, data centers, or renewable energy projects, Shinenergy’s transformers are designed to optimize power systems, reducing operational costs and improving overall efficiency.

With a strong focus on providing customized solutions, Shinenergy combines cutting-edge technology with flexible options tailored to the specific requirements of your project. Our transformers not only ensure the safety and stability of your power supply but also help you maximize return on investment by enhancing energy efficiency. Choosing Shinenergy means adopting a reliable, efficient power management solution that positions your business for sustained growth and long-term competitive advantage in the marketplace.

Contact us today to discover how Shinenergy’s Three Phase 240V to 100V Step Down Transformers can boost your operational efficiency, reduce energy costs, and help your business thrive in an increasingly competitive environment.

What is the difference between a step-up transformer and a step-down transformer?

A step-up transformer increases the voltage from the primary winding to the secondary winding, while a step-down transformer reduces the voltage. In the case of a Three Phase Step Down Transformer 240V to 100V, it reduces the voltage from 240V to 100V, making it ideal for supplying power to equipment that requires lower voltage levels in various industrial and commercial applications. Step-up transformers are typically used when a higher voltage output is needed for long-distance power transmission, whereas step-down transformers are essential for reducing high voltage to safer, more manageable levels for operational use in day-to-day equipment.
For more information, feel free to contact us.

What is the step-down transformer diagram?

A typical wiring diagram for a Three Phase Step Down Transformer 240V to 100V shows how the primary winding, with more wire turns, and the secondary winding, with fewer wire turns, effectively reduce the voltage from 240V on the primary side to 100V on the secondary side. This configuration ensures a safe and efficient voltage conversion process, which is crucial for maintaining reliable power in industrial and commercial applications.
For more information, feel free to contact us.

What does a step-down transformer do?

A Three Phase Step Down Transformer 240V to 100V reduces the voltage from 240V on the primary side to 100V on the secondary side, making it an ideal solution for powering equipment that operates at lower, safer voltage levels. This transformer plays a critical role in improving the reliability and safety of your power distribution system, ensuring the smooth operation of various industrial and commercial machinery.
For more information, feel free to contact us.

How does a step-down transformer work?

A Three Phase Step Down Transformer 240V to 100V works based on the principle of electromagnetic induction. When alternating current flows through the primary winding (240V), it generates a magnetic field within the core of the transformer, which induces a lower voltage (100V) in the secondary winding. The voltage reduction occurs because the secondary winding has fewer wire turns compared to the primary, allowing the transformer to step down the voltage to a safe and efficient level suitable for your equipment.
For more information, feel free to contact us.

What is the step-down transformer formula?

The formula for a Three Phase Step Down Transformer 240V to 100V compares the primary and secondary voltages with the number of turns in each winding:

Vs / Vp = Ns / Np

Where:

  • Vs= secondary voltage (100V)
  • Vp= primary voltage (240V)
  • Ns= number of turns on the secondary winding
  • Np= number of turns on the primary winding

Since the number of turns on the secondary winding (Ns) is fewer than the number of turns on the primary winding (Np), the voltage on the secondary side (100V) is reduced compared to the primary side (240V). This ensures a stable and controlled voltage output for your applications.
For more information, feel free to contact us.

Send Your Inquiry
Quick Quote
Scroll to Top