Three Phase 240v to 120v step down transformer
Your Transformer & Inductor Manufacture

Three Phase 240v to 120v step down transformer

Custom Transformer Specifications:

  • UL Certification standards
  • 10KVA-3000KVA Rated power
  • 50Hz/60 Hz Frequency
  • 80°C -150°C Temperature Rise
  • Class F/H/N/R Insulation Class
  • Copper/Aluminum winding materials
  • Δ-Y/Y-Y /Δ-Δ /Y-Δ/Δ-Z/Y-Z/ Wiring Configurations
  • IP00/IP20/IP23/IP40/IP44/IP54
  • Vacuum Pressure Impregnated Windings
  • Energy Efficient

Maximizing Solar Power Efficiency | Shinenergy Three Phase 240V to 120V Step Down Transformer

Shinenergy’s three-phase step down transformers provide stable voltage conversion for photovoltaic (PV) systems, efficiently converting 240V to 120V, ensuring that solar systems always operate under optimal conditions. Our products not only dramatically improve energy conversion efficiency, but also help customers achieve a higher return on investment in their PV projects through customized solutions. With in-depth knowledge of market trends, Shinenergy’s solutions optimize system performance and ensure that our customers stand out from the competition. Choosing Shinenergy means not only improving system efficiency but also maximizing the return on your PV investment.

Enhancing Energy Storage Efficiency | Shinenergy Three Phase 240V to 120V Step Down Transformer

Shinenergy’s three-phase step down transformers are the key to boosting the performance of energy storage systems, converting 240V to 120V with precision and significantly improving power conversion efficiency. Our customized solutions for the energy storage industry not only ensure long-term stability of the system, but also help customers solve power management challenges and further reduce operating costs through flexible services. Choosing Shinenergy means maximizing the benefits of your energy storage system and ensuring your business stays ahead of future energy demands.

Enhancing Data Center Power Reliability | Shinenergy Three Phase 240V to 120V Step Down Transformer

Data centers have stringent requirements for power reliability and efficiency, and Shinenergy’s three-phase step down transformers convert 240V to 120V in a stable manner to provide continuous power support for data centers. Our products help customers reduce the risk of downtime and prevent voltage fluctuations from impacting IT infrastructure, while optimizing power management and reducing energy costs. By partnering with Shinenergy, you will not only improve the operational efficiency of your data center, but also increase your competitiveness and ensure that your systems continue to operate safely and efficiently.

Powering Wind and Hydrogen Energy Systems | Shinenergy Three Phase 240V to 120V Step Down Transformer

Designed for renewable energy projects such as wind and hydrogen, Shinenergy’s three-phase step down transformers provide reliable voltage conversion in extreme environments to ensure efficient operation. Our technological solutions help customers achieve sustainable green energy projects by optimizing operational efficiency and reducing costs. As a leading technology provider, Shinenergy continues to drive innovation to ensure our customers stay ahead of the market. By choosing Shinenergy, you will not only improve the operational efficiency of your project, but also realize the long-term commercial returns of your green energy project.

Ensuring Medical Power Stability | Shinenergy Three Phase 240V to 120V Step Down Transformer

In the medical industry, where power stability and safety are of paramount importance, Shinenergy’s three-phase step down transformers are manufactured in accordance with medical industry standards to ensure a safe transition from 240V to 120V for the continuous operation of critical medical equipment. Our solutions not only improve the efficiency of power management in hospitals, but also ensure the continuous operation of equipment, minimizing the risk of downtime and improving the continuity of healthcare services. By partnering with Shinenergy, you can focus on improving the quality of patient care, while we provide you with reliable power support to help you increase your hospital’s operational efficiency and patient satisfaction.

Certification UL
Phase Three Phase
Rated capacity UP TO 3000KVA Customized
Frequency 50/60Hz
Work Efficiency UP TO 99.05%
Protection Class IP00/IP20/IP23/IP40/IP44/IP54
Winding Material Copper or Aluminum
Insulation level Class F (155°C) Class H (180°C) Class N (200°C) Class R (220°C)
Designed lifetime ≥30 years
Cooling Method Air Cooling
Wiring Configuration Δ-Y (Delta-Star)/Y-Y (Star-Star)/Δ-Δ (Delta-Delta)/Y-Δ (Star-Delta) /Δ-Z (Delta-Zigzag)/ Y-Z (Star-Zigzag)
Noise ≤35 dB (1 meter)
Step Down Three Phase Transformer catalog
Step Down Three Phase 480 to 240 transformer Step Down Three Phase 480 208 transformer Step Down Three Phase 480/220 transformer Step Down Three Phase 480 to 230 transformer Step Down Three Phase 480 to 400 volt transformer 480v to 230v 3 phase transformer
Step Down Three Phase 240v to 110v transformer Three Phase 240v to 120v step down transformer Three Phase 240 to 208 step down transformer Three Phase 120v to 100v step down transformer Three Phase 600v to 220v step down transformer Step Down Three Phase 208v to 120v transformer
Three Phase step down transformer 220v to 110v Three Phase 440 to 220 step down transformer Three Phase 460 to 230 step down transformer 3 phase Three Phase step down transformer 240v to 100v Three Phase 240v to 220v step down transformer Three Phase step down transformer 480 to 120
Three Phase 480 to 220 step down transformer Three Phase 480 to 230 step down transformer Three Phase 600v to 110v step down transformer Three Phase 600v to 120v step down transformer Three Phase 240v to 100v step down transformer Three Phase step down transformer 277 to 120
Rated capacity
1kva step down transformer 2kva step down transformer 5kva step down transformer 5 kva step down transformer 10 kva step up transformer 10kva step down transformer 15 kva step down transformer 20 kva step down transformer
25 kva step down transformer 30kva step down transformer 30 kva step down transformer 45 kva step down transformer 50 kva step down transformer 75 kva step down transformer 150 kva step down transformer 500 kva step down transformer
500 watt transformer 1000 watt transformer 1000w step down transformer 1500w step down transformer 1500 watt transformer 2000w step down transformer 2000 watt step down transformer 3000w step down transformer
5000w transformer 5000 watt step down transformer 5000w step down transformer 10000 watts step up down transformer 10000 watt step down transformer 20000 watts step down transformer

Releted Products

Enhance Power Efficiency with Shinenergy’s Step Down Three Phase 240V to 120V Transformer

Shinenergy’s** Step Down Three Phase 240V to 120v Transformer** provides a reliable power conversion solution for industrial and commercial projects. By steadily stepping down  240V to 120V, our transformers ensure that your equipment operates efficiently in any application, optimizing energy efficiency and reducing the risk of system failure. Whether you’re in manufacturing, a data center, or the energy industry, Shinenergy’s transformers can help you improve power management efficiency, reduce operating costs, and improve the long-term stability of your equipment.

Shinenergy is committed to providing customized solutions to meet the unique needs of our customers. Our transformers not only comply with international standards but can also be optimally configured to meet your project’s specific requirements, helping you to maximize energy efficiency and improve your return on investment. When you choose Shinenergy, you get efficient, safe, and reliable power solutions that help your business grow and gain an edge over the competition.

Contact us to learn how you can realize greater operational efficiency and market competitiveness with Shinenergy’s step-down transformer technology.

What is the difference between a step up transformer and a step down transformer?

A step-up transformer increases the voltage from the primary winding to the secondary winding, while a step-down transformer reduces the voltage. Step-up transformers are used in situations where higher voltage output is necessary, while step-down transformers lower the voltage to safer, more practical levels for use.

For more information, feel free to contact us.

What is the step down transformer diagram?

A typical 240v to 120v transformer wiring diagram depicts the primary winding with more wire turns and the secondary winding with fewer turns. This configuration explains how the voltage is reduced as it moves from the primary to the secondary side.

For more information, feel free to contact us.

What does a step down transformer do?

A step-down transformer decreases the voltage from the higher primary side to the lower secondary side, making it ideal for applications that require a lower, safer voltage output.

For more information, feel free to contact us.

How does a step down transformer work?

A step-down transformer operates based on electromagnetic induction. Alternating current in the primary winding generates a magnetic field in the core, inducing a lower voltage in the secondary winding due to fewer wire turns compared to the primary.

For more information, feel free to contact us.

What is the step down transformer formula?

The formula for a step-down transformer compares the primary and secondary voltages with the number of turns in the windings:

Vs / Vp = Ns / Np

Where:

 

Vs = secondary voltage,

Vp = primary voltage,

Ns = turns on the secondary winding,

Np = turns on the primary winding.

In a step-down transformer, since Ns is less than Np, the secondary voltage (Vs) will be lower than the primary voltage (Vp).

For more information, feel free to contact us.