460 to 230 Step Down Transformer 3 Phase
Custom Transformer Specifications
- UL Certification standards
- 10KVA-3000KVA Rated power
- 50Hz/60 Hz Frequency
- 80°C -150°C Temperature Rise
- Class F/H/N/R Insulation Class
- Copper/Aluminum winding materials
- Δ-Y/Y-Y /Δ-Δ /Y-Δ/Δ-Z/Y-Z/ Wiring Configurations
- IP00/IP20/IP23/IP40/IP44/IP54
- Vacuum Pressure Impregnated Windings
- Energy Efficient
Maximizing Solar Power Efficiency | Shinenergy Three Phase 460 to 230 Step Down Transformer
Shinenergy’s Three Phase 460 to 230 Step Down Transformer is specifically designed to meet the stringent demands of photovoltaic (PV) systems, delivering precise and reliable voltage conversion for optimized solar energy performance. By stepping down 460V to 230V, our transformers significantly enhance energy conversion efficiency, enabling customers to maximize their returns on solar energy investments. With our deep industry expertise and customized solutions, Shinenergy helps businesses fine-tune system performance, ensuring they stay ahead in the competitive renewable energy market. Choosing Shinenergy means elevating both the operational efficiency and financial profitability of your solar projects for long-term sustainability and success.
Enhancing Energy Storage System Performance | Shinenergy Three Phase 460 to 230 Step Down Transformer
Shinenergy’s Three Phase 460 to 230 Step Down Transformer is a key component in optimizing energy storage systems, providing consistent and efficient voltage conversion. By stepping down 460V to 230V with precision, our transformers improve power conversion, ensuring stable performance across your energy storage infrastructure. Built for the energy storage industry, Shinenergy’s tailored solutions deliver long-term system stability while tackling power management challenges and reducing operational costs. Partnering with Shinenergy unlocks the full potential of your energy storage solutions, empowering your business to meet future energy demands and maintain profitability in a rapidly evolving marketplace.
Ensuring Data Center Power Reliability | Shinenergy Three Phase 460 to 230 Step Down Transformer
In the data center industry, where power reliability and efficiency are essential, Shinenergy’s Three Phase 460 to 230 Step Down Transformer ensures precise and stable voltage conversion for uninterrupted operations. Our transformers are engineered to prevent costly downtimes, safeguard IT infrastructure from voltage fluctuations, and optimize overall power management—all while reducing energy expenses. By choosing Shinenergy, you can enhance the operational efficiency, stability, and competitiveness of your data center, ensuring continuous, reliable, and secure performance in a demanding market.
Powering Wind and Hydrogen Energy Projects | Shinenergy Three Phase 460 to 230 Step Down Transformer
Built to meet the high demands of renewable energy projects such as wind and hydrogen, Shinenergy’s Three Phase 460 to 230 Step Down Transformer ensures reliable and efficient voltage conversion even in the most challenging environmental conditions. Our transformers support efficient power management, allowing your renewable energy projects to achieve peak operational performance. Leveraging Shinenergy’s advanced technology, businesses can optimize their renewable operations while lowering costs, driving sustainable energy success. Partnering with Shinenergy guarantees not only long-term commercial returns but also supports the global transition to a cleaner, greener energy future.
Ensuring Medical Power Stability | Shinenergy Three Phase 460 to 230 Step Down Transformer
In the medical industry, where power stability and safety are critical to the continuous operation of life-saving equipment, Shinenergy’s Three Phase 460 to 230 Step Down Transformer delivers precise and dependable voltage conversion. Designed to meet strict industry standards, our transformers safeguard critical medical devices, improving hospital power management and minimizing downtime. By partnering with Shinenergy, you ensure that your healthcare facility maintains stable power supply, enabling healthcare professionals to focus on patient care while we support the overall efficiency and reliability of your medical infrastructure.
- Data Sheet
- Step Down Three Phase Transformer catalog
- Rated capacity
Certification | UL |
Phase | Three Phase |
Rated capacity | UP TO 3000KVA Customized |
Frequency | 50/60Hz |
Work Efficiency | UP TO 99.05% |
Protection Class | IP00/IP20/IP23/IP40/IP44/IP54 |
Winding Material | Copper or Aluminum |
Insulation level | Class F (155°C) Class H (180°C) Class N (200°C) Class R (220°C) |
Designed lifetime | ≥30 years |
Cooling Method | Air Cooling |
Wiring Configuration | Δ-Y (Delta-Star)/Y-Y (Star-Star)/Δ-Δ (Delta-Delta)/Y-Δ (Star-Delta) /Δ-Z (Delta-Zigzag)/ Y-Z (Star-Zigzag) |
Noise | ≤35 dB (1 meter) |
Step Down Three Phase 480 to 240 transformer | Step Down Three Phase 480 208 transformer | Step Down Three Phase 480/220 transformer | Step Down Three Phase 480 to 230 transformer | Step Down Three Phase 480 to 400 volt transformer | 480v to 230v 3 phase transformer |
Step Down Three Phase 240v to 110v transformer | Three Phase 240v to 120v step down transformer | Three Phase 240 to 208 step down transformer | Three Phase 120v to 100v step down transformer | Three Phase 600v to 220v step down transformer | Step Down Three Phase 208v to 120v transformer |
Three Phase step down transformer 220v to 110v | Three Phase 440 to 220 step down transformer | Three Phase 460 to 230 step down transformer 3 phase | Three Phase step down transformer 240v to 100v | Three Phase 240v to 220v step down transformer | Three Phase step down transformer 480 to 120 |
Three Phase 480 to 220 step down transformer | Three Phase 480 to 230 step down transformer | Three Phase 600v to 110v step down transformer | Three Phase 600v to 120v step down transformer | Three Phase 240v to 100v step down transformer | Three Phase step down transformer 277 to 120 |
Rated capacity | |||||||
1kva step down transformer | 2kva step down transformer | 5kva step down transformer | 5 kva step down transformer | 10 kva step up transformer | 10kva step down transformer | 15 kva step down transformer | 20 kva step down transformer |
25 kva step down transformer | 30kva step down transformer | 30 kva step down transformer | 45 kva step down transformer | 50 kva step down transformer | 75 kva step down transformer | 150 kva step down transformer | 500 kva step down transformer |
500 watt transformer | 1000 watt transformer | 1000w step down transformer | 1500w step down transformer | 1500 watt transformer | 2000w step down transformer | 2000 watt step down transformer | 3000w step down transformer |
5000w transformer | 5000 watt step down transformer | 5000w step down transformer | 10000 watts step up down transformer | 10000 watt step down transformer | 20000 watts step down transformer |
Boost Operational Performance with Shinenergy’s Three Phase 460V to 230V Step Down Transformer
Shinenergy’s Three Phase 460V to 230V Step Down Transformer is designed to meet the demanding needs of industrial and commercial power applications. By efficiently converting 460V to 230V, our transformers provide stable and reliable power, reducing energy consumption while minimizing equipment downtime and failure risks. Whether your business operates in manufacturing, data centers, or renewable energy projects, Shinenergy’s transformers optimize power usage, driving down operational costs and enhancing overall efficiency.
At Shinenergy, we are committed to offering tailored solutions. Our transformers are equipped with advanced technology and customizable options to perfectly fit the unique requirements of your project. Not only do they ensure safe and consistent power supply, but they also maximize your return on investment by improving energy efficiency. Choosing Shinenergy ensures your business benefits from a dependable and innovative power management solution that supports long-term growth and sustained competitive advantage.
Contact us today to discover how Shinenergy’s Three Phase 460V to 230V Step Down Transformers can improve your operational efficiency, lower energy costs, and propel your business toward a more sustainable and profitable future.
The main difference between Step-up and Step-down transformers is the direction in which the voltage is regulated; Step-up transformers step up the voltage, making them suitable for long distance power transmission, while Step-down transformers step down the voltage, converting the high voltage to a safer level more suited to the actual application. The Three Phase 460V to 230V Step Down Transformer, for example, reduces the high voltage of 460V to 230V, making it suitable for industrial and commercial equipment that requires low voltage to ensure safe and efficient operation.
Want to know more? Please feel free to contact us.
In a typical Three Phase 460V to 230V Step Down Transformer wiring diagram, you can see that the primary winding converts a high voltage to a lower voltage in the secondary winding through a higher number of coils. By reducing the number of winding turns, the voltage is successfully stepped down from 460V to 230V, ensuring safe and efficient power conversion. This configuration is critical in a variety of industrial and commercial scenarios, helping to maintain a stable and reliable power distribution.
For further information, please feel free to contact us.
A Three Phase 460V to 230V Step Down Transformer reduces the voltage from 460V on the primary side to 230V on the secondary side, providing a safe and efficient solution for powering equipment that operates at lower voltage levels. This transformer ensures reliable power delivery, improving the overall safety and efficiency of your power distribution system, which is crucial for seamless operations in a variety of industrial and commercial environments.
For more information, feel free to contact us.
A Three Phase 460V to 230V Step Down Transformer operates using electromagnetic induction. When alternating current passes through the primary winding (460V), it generates a magnetic field within the transformer core, inducing a lower voltage (230V) in the secondary winding. The voltage reduction occurs because the secondary winding has fewer wire turns compared to the primary winding, allowing the transformer to precisely step down the voltage to a safe and manageable level for efficient use.
For more information, feel free to contact us.
The formula for a Three Phase 460V to 230V Step Down Transformer is as follows: Vs / Vp = Ns / Np
where
Vs = secondary voltage (230V)
Vp = Primary voltage (460V)
Ns = number of coils in secondary winding
Np = number of coils in the primary winding
Since the number of coils in the secondary winding is less than that in the primary winding, the secondary voltage (230V) will be lower than the primary voltage (460V), ensuring a safe and controlled output voltage.
Want to know more? Contact us!