Custom Transformer Specifications

  • UL Certification standards
  • 10KVA-3000KVA Rated power
  • 50Hz/60 Hz Frequency
  • 80°C -150°C Temperature Rise
  • Class F/H/N/R Insulation Class
  • Copper/Aluminum winding materials
  • Δ-Y/Y-Y /Δ-Δ /Y-Δ/Δ-Z/Y-Z/ Wiring Configurations
  • IP00/IP20/IP23/IP40/IP44/IP54
  • Vacuum Pressure Impregnated Windings
  • Energy Efficient

Boost Solar Power Efficiency with Shinenergy's Single Phase Step Up Transformers (208V to 480V)

Shinenergy specializes in single phase step up transformers for photovoltaic (PV) applications, converting 208V to 480V efficiently. Our transformers enhance voltage levels, optimizing the performance and reliability of solar power systems. With tailored solutions and extensive PV experience, Shinenergy helps maximize your solar energy output, making us a trusted partner for renewable energy projects.

Optimize Energy Storage with Shinenergy's Single Phase Step Up Transformers (208V to 480V)

Shinenergy’s single phase step up transformers are essential for energy storage systems, boosting voltage from 208V to 480V to ensure safety and efficiency. Designed to meet the demands of battery storage, our transformers provide reliable power conversion and long-term stability, helping you maintain optimal performance and secure energy operations.

Reliable Power Supply for Data Centers with Shinenergy's Single Phase Step Up Transformers (208V to 480V)

Data centers need consistent power, and Shinenergy’s single phase step up transformers are built to deliver just that, converting 208V to 480V with precision. Our transformers provide stable, regulated power, protecting critical IT infrastructure from disruptions. Trust Shinenergy to enhance your data center’s reliability and efficiency, minimizing downtime and safeguarding operations.

Shinenergy's Single Phase Step Up Transformers (208V to 480V) for Wind and Hydrogen Projects

Shinenergy provides robust single phase step up transformers designed for wind energy and hydrogen production, effectively converting 208V to 480V. Our transformers withstand extreme conditions, ensuring efficient power conversion and supporting the growth of sustainable energy projects. Choose Shinenergy for durable solutions that enhance the efficiency of renewable energy systems.

Ensure Safe Power in Healthcare with Shinenergy's Single Phase Step Up Transformers (208V to 480V)

The formula for a Step Up Transformer shows the relationship between the primary and secondary voltages and the number of turns in each winding:

In healthcare, reliable power is crucial. Shinenergy’s single phase step up transformers safely convert 208V to 480V, providing stable voltage for sensitive medical equipment. Built to meet strict medical standards, our transformers ensure dependable power delivery in critical environments, supporting optimal patient care and operational effectiveness.

Certification UL
Phase Single Phase
Rated capacity UP TO 3000KVA Customized
Frequency 50/60Hz
Work Efficiency UP TO 99.05%
Protection Class IP00/IP20/IP23/IP40/IP44/IP54
Winding Material Copper or Aluminum
Insulation level Class F (155°C) Class H (180°C) Class N (200°C) Class R (220°C)
Designed lifetime ≥30 years
Cooling Method Air Cooling
Wiring Configuration Δ-Y (Delta-Star)/Y-Y (Star-Star)/Δ-Δ (Delta-Delta)/Y-Δ (Star-Delta) /Δ-Z (Delta-Zigzag)/ Y-Z (Star-Zigzag)
Noise ≤35 dB (1 meter)

Releted Products

Efficient Power Conversion with Single Phase Step Up Transformers (208V to 480V) by Shinenergy

designed to convert 208V to 480V, ensuring efficient power delivery for various applications. Our transformers are built with superior materials and advanced engineering, providing reliable voltage boosting to enhance the performance of your electrical systems. Ideal for industrial, commercial, and residential use, Shinenergy’s step up transformers ensure smooth and stable power conversion, reducing energy loss and optimizing your operations. Choose Shinenergy for quality and reliability in power solutions. Contact us today to learn more about our customizable transformer options.

What is the difference between a Step Up Transformer and a Step Down Transformer?

A Step Up Transformer increases the voltage from the primary winding to the secondary winding, resulting in a higher output voltage than the input voltage. Conversely, a Step Down Transformer decreases the voltage, resulting in a lower output voltage than the input voltage. Both types of transformers are used to modify voltage levels to meet the specific needs of different electrical systems.

What is the Step Up Transformer diagram?

A Step Up Transformer diagram typically shows the primary winding with fewer turns of wire and the secondary winding with more turns. This configuration demonstrates how the transformer boosts the voltage from the primary side to the secondary side. The diagram also includes a magnetic core that facilitates the transfer of electrical energy through electromagnetic induction.

What does a Step Up Transformer do?

A Step Up Transformer increases the AC voltage from a lower level on the primary side to a higher level on the secondary side. This is particularly useful for transmitting power over long distances, as higher voltages help to minimize energy loss during transmission.

How does a Step Up Transformer work?

A Step Up Transformer operates based on the principle of electromagnetic induction. When an alternating current flows through the primary winding, it generates a magnetic field in the core. This magnetic field induces a higher voltage in the secondary winding, which has more turns of wire than the primary winding, thereby stepping up the voltage.

What is the Step Up Transformer formula?

The formula for a Step Up Transformer shows the relationship between the primary and secondary voltages and the number of turns in each winding:

Vs / Vp = Ns / Np

where:

  • Vs is the secondary voltage,
  • Vp is the primary voltage,
  • Ns is the number of turns on the secondary winding, and
  • Np is the number of turns on the primary winding.

In a Step Up Transformer, the secondary winding has more turns than the primary winding (Ns > Np), which results in a higher secondary voltage (Vs > Vp).